FEATURES,
SPECIFICATIONS
AND BENEFITS |
MODEL 1042LH |
|
APPLICATION |
Flow-through humidifier that’s
ideal for most homes. Installs on vertical warm air supply or cold air
return plenum. |
|
UNIT SIZE |
15" wide x 11-1/2" high x 9" deep |
|
PLENUM OPENING |
10-1/4" wide x 9-1/2" high |
|
BYPASS DUCT |
6" diameter (collar supplied) |
EVAPORATIVE OUTPUT CAPACITY @
.20"
PRESSURE DIFFERENTIAL
(except 747 rated at 800 FPM duct velocity)
ABOVE AT STANDARD INDUSTRY RATING CONDITIONS |
|
Temp°F
|
GPD
|
Temp°F
|
GPD
|
| 80° |
8.0 |
140° |
19.2 |
| 100° |
12.2 |
160° |
23.2 |
| 120° |
16.4 |
|
|
|
|
EVAPORATIVE PRINCIPLE
GENERALAire humidifers are 100% evaporative, adding moisture in the form of
water vapor only. They are clean operating. The nuisance of airborne water
droplets or mineral dust is avoided. |
Note: 140° hot water supplied to
the humidifier in heat pump applications will increase capacity 4.3 GPD. |
|
EVAPORATIVE PRINCIPLE
GENERALAire humidifers are 100% evaporative, adding moisture in the form of
water vapor only. They are clean operating. The nuisance of airborne water
droplets or mineral dust is avoided. |
Forced warm air heating systems
create a pressure differential that diverts some heated air to the
humidifier through a bypass duct. There, the warm air absorbs moisture from
a water-soaked evaporator pad and then rejoins the primary warm air stream
for distribution throughout the living area. A solenoid valve and patented
distribution tray meter and disperse water uniformly across the evaporator
pad. Unevaporated water drains from the unit. |
|
EVAPORATIVE MEDIA |
990-13 Evaporator Pad. Designed
for high output with minimal hard water scale accumulation. UL listed. |
|
WATER SUPPLY |
Dependable stainless steel
solenoid valve with monel wire mesh filter that protects the precision
machined Teflon flow-control orifice. Saddle valve supplied. Use 1/4" copper
tubing. |
|
DRAIN CONNECTION |
High capacity 5/8" drain and hose
prevents clogging. Includes 15' vinyl hose except recircating models. |
|
RANGE OF MODELS |
1042 – line voltage
1042-L – low voltage
1042-LH – low voltage w/H-86 Humidistat
1042-R – recirculating, no drain required, with time-tested Model 975
Recirculating Pump |
|
ELECTRICAL |
1042 – 115 V. 60 Hz.
1042-L – 24 V. 60 Hz.
1042-LH – 24 V. 60 Hz.
1042-R – 115 V. 60 Hz.
(L/LH models – transformer supplied) |
|
CONTROLS |
Manual air shutter for summer
shut-off affords some control of humidifier output. Model 1042 LH includes
GENERALAire H-86 wall/duct mount humidistat. |
CONSTRUCTION,
MATERIALS AND STYLING |
Attractive cabinet made from
durable,non-corrosive, high temperature materials for long service life. |
|
VERSATILITY |
Right or left hand bypass
installation. May be installed on up-flow, counter-flow or horizontal
furnaces or air handlers. |
|
SERVICEABILITY |
Thumbscrews allow easy access to
distribution trough, drain pan and evaporative pad for quick, easy cleaning
and service. |
|
EASY INSTALLATION – GENERALAire
humidifers are specially designed for fast, easy installation |
Most important components are
included. Outboard and keyholed screw holes and simple thumbscrew assembly
speeds installation. Patented water distribution tray reduces need for
critical leveling. |